Insulation ratings can be improved by adding more layers of insulation.
Wisconsin attic insulation code.
The higher the r value the better the thermal performance of the insulation.
B an attic access cover shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces when the attic is an unconditioned space.
Sps 322 01 3 b b the vapor retarder requirements under s.
Duct insulation supply and return ducts in unconditioned space insulated to a minimum of r 8 hot water pipe insulation heating pipe in unheated spaces shall be insulated with a minimum of r 4.
You can mix the type and material of insulation too.
The 2015 irc requires r 49 insulation for ceilings with attic spaces.
Comcheck is federal department of energy doe software approved in wisconsin for demonstrating compliance with commercial building envelope requirements and interior exterior general lighting requirements only hvac portions of the program are not acceptable.
The ideal attic insulation r value is different than the ideal wall insulation r value.
Sps 322 38 do not apply to an unheated space such as an attached unheated garage.
However there is an exception.
Find your zone on the map and then use the chart to determine the level of insulation you need to properly insulate your attic walls floors and crawlspaces.
R value is a measure of insulation s ability to resist heat traveling through it.
The table below shows what levels of insulation are cost effective for different climates and locations in the home.
This map shows thermal recommended levels of insulation for various climate zones based on recommendations from the u s.
You should select a loose fill r 49 insulation product.
Comcheck can be used for commercial buildings or high rise 3 stories multi family buildings.
Achieving greater r values in attics.
Insulation rated at r 60 can place too much weight on a plaster ceiling which can cause the laths under the plaster ceiling below to loosen from the ceiling joists.
Pa302 1 ceilings with attic spaces n1102 2 1 r402 2 1.
Sps 322 39 apply to any dwelling with insulation installed whether or not the insulation is required under this code.
Achieving greater r values in attics the higher the r value the better the thermal performance of the insulation.
An unheated and unfinished attic space in wisconsin needs insulation rated between r 49 and r 60.
All of the referenced codes listed below were adopted in the mid to late.
The first state building code in wisconsin was established in 1914.
The iecc is the model building code for the united states.
Department of energy doe and the international energy conservation code iecc.
Insulation level are specified by r value.
Recommended levels of insulation.